Testing In-Service Upgrade for HCX Network Extension Appliances

HCX 4.0 introduced plenty of new features and functionalities, such as migration details and security tag migrations to name a few. One of the features I like the most is In-Service Upgrade for the network extension appliance(s). While the standard upgrade re-deploys the network extension (NE) appliance, the in-service upgrade will deploy an extra appliance with a new set of IPs prior to removing the old appliance. This will allow HCX to establish a tunnel between the two new appliances and then do a switchover to minimize downtime for the extended networks.

To compare the downtime the extended networks experience using each upgrade method, I tested the impact of each one on the connectivity between two VMs while redeploying the NE appliances. You can read about the steps I performed or jump straight to the test conclusion:

This test was performed in my lab environment, so the actual results in other environments may vary

Test Environment Overview

Test Environment Diagram

To perform the test I am using my home lab, located in Chicago, and a VMware Cloud on AWS SDDC in Oregon (us-west-2). Both sites are connected via route-based VPN and have HCX deployed and a service mesh configured:

HCX Service Mesh

A single network, site1-vlan11, is extended between the sites. The CIDR range is 172.25.11.0/24 and my lab’s pfSense functions as the default gateway for the network. The pfSense is also the default gateway of the other network I’m using, core-vlan10 which uses CIDR 172.25.10.0/24

HCX Network Extension

The following VMs were used to test the connectivity:

Name Location Portgroup IP Address OS
core-mint On-prem core-vlan10 172.25.10.212 Linux Mint
sdcoffee-vlan11 VMW on AWS L2E_site1-vlan11-11-189c7e98 172.25.11.236 Photon OS
Remote Cloud VM

Before running the tests, the NE appliance on-prem is deployed with the following IPs:

Traffic type IP
Management Network 172.25.10.22
Uplink Network 192.168.1.222
NE Appliance IPs - Start

To simulate the process that occurs during an appliance upgrade I opted to redeploy the appliances, as this gives me the option of running the test several times without needing to wait for a new version to upgrade to. To redeploy the appliances, follow these steps:

  1. Open the HCX plugin in vCenter or connect to the HCX manager
  2. Select Interconnect and then the Service Mesh tab
  3. Under the service mesh you’d like to test, click View Appliances
  4. Select the NE appliance and click Redeploy
  5. You’d then have the option of selecting Standard or In-Service mode
  6. Once the redeployment is initiated, the specific steps and actions taken can be viewed in the Tasks tab
HCX Redeploy

Standard Upgrade

Before redeploying the NE appliance I launched the following ping command from core-mint, which provides a timestamp and will also show failed ping packets:

ping -i 1 -O 172.25.11.236 | ts "%H:%M:%.S"

Next, I redeployed the NE appliance using Standard mode:

NE Redeployment - Standard

During the redeployment process, a new NE appliance will be deployed in both the source and destination sites. In this screenshot, we can see that a new NE appliance is deployed on-prem with the same IPs as the original appliance:

NE Appliance IPs - Standard

After a couple of minutes, HCX will start configuring the connectivity between the two new NE appliances:

NE redeploy task list - Standard

During this step, the tunnel is being established between the two appliances, which means downtime for the extended networks. In my environment the VMs lost connectivity for a little under 25 seconds:

Ping test - Standard

Once the tunnel is up and running HCX will remove the original appliances and will rename them.

In-Service Upgrade

Similar to the steps performed in the standard mode test, I started a continuous timestamped ping from core-mint. However, when running the same command as I did previously for the first couple of tests I did not see any loss of packets (which is very promising!). Because of that, I changed the ping frequency to 200ms, which is the minimum possible:

ping -i 0.2 -O 172.25.11.236 | ts "%H:%M:%.S"

Next, I redeployed the NE appliance using In-Service mode:

NE Redeployment - Standard

Once again, a new NE appliance will be deployed in both the source and destination sites. This time, as seen in the screenshot of the on-prem environment, the new NE appliance is deployed using a different set of IPs:

NE Appliance IPs - In-Service

As a comparison, here are the IPs of the original and newly deployed NE appliance on-prem:

Interface Original NE Appliance New NE Appliance
Management IP 172.25.10.22 172.25.10.24
Uplink IP 192.168.1.222 192.168.1.224

Since In-Service is using a new set of appliances with different IP addresses the tunnel configuration between them doesn’t impact existing traffic. Instead, workloads are only experiencing a short amount of downtime during a new step, the NetExt Switchover:

NE redeploy task list - In-Service

Before this step, there are two sets of appliances with a tunnel established between them. During this step, the network extensions are switched over to the tunnel between the two new appliances. In my environment the VMs lost connectivity for just a little more than a second:

Ping test - In-Service

Again, once the extensions are switched over to the new appliances HCX will remove the original appliances and rename them.

Conclusion

Here is the summary of the results I got in the tests of the two upgrade/redeployment modes:

Metric Standard Mode In-Service Mode
Network Downtime 24.55 Seconds 1.02 Seconds
Preparation None Required - Additional IP per NE appliance upgraded/redeployed
- Service mesh must be in a healthy state
- HCX 4.0 and above

Just as a reminder, this was tested in my lab environment so your mileage may vary. That being said, the difference between the two modes is quite significant. While 25 seconds will definitely impact applications, most shouldn’t even notice a 1 second outage, which is similar to what is experienced during vMotion.

Since most of the downtime the HCX extended networks experience is planned due to upgrades, In-Service mode can significantly improve the availability of workloads connected to extended networks.

Asaf Blubshtein
Asaf Blubshtein
Product Solutions Architect, VMware Cloud

My current role focuses on enabling VMware Cloud. I spend the rest of my time with my wife, our two cats, my home-lab, and our espresso machine.

Previous